Heater shutting off in a San Antonio cold snap
The burners lit and went out within seconds. A coated flame sensor was the cause.
-
The problem
On the first cold night of the year the furnace started, ran for a few seconds, shut off and tried again, over and over.
-
What we found
The burners lit normally, but the flame sensor was not confirming the flame, so the control shut the gas off each time. The sensor rod was coated. Venting and gas pressure checked out, and the filter was dirty.
-
The options
Clean the flame sensor and change the filter, or replace the sensor if it was damaged. It cleaned up well, so replacement was not needed.
-
What was done
The sensor was cleaned, the filter replaced, and the furnace was run through several full heating cycles while the safety controls were checked.
-
The outcome
The furnace runs full cycles again. The homeowner was shown the filter and how often to check it.
Photos from the job
-
View larger photo
Burners lighting normally through the viewing window. -
View larger photo
The coated flame sensor rod. -
View larger photo
A new filter in the return.
More project stories
-
AC Repair Alamo Heights
Short-cycling AC traced to an oversized system
The AC turned on and off every few minutes and the house felt clammy. The system was much larger than the home needed.
-
AC Maintenance San Antonio
A slow drain line caught during a maintenance visit
During a spring check, a partly blocked condensate drain was cleared before it could overflow.
-
AC Installation Converse
Replacing a 19-year-old system in Converse: options compared
An R-22 system with a refrigerant leak. The homeowner compared another repair with two replacement options before deciding.